First, the pneumatic O-cut ball valve overview
Pneumatic
O-cut ball valve pneumatic actuator using the new AT / GT series of
pneumatic actuators, the structure of the national utility model
patents, a double-acting and single-acting type (spring reset), the use
of rack and pinion Structural transmission, the performance is more
secure and reliable.
Second, pneumatic O-cut ball valve introduction
Pneumatic
O-cut ball valve pneumatic actuator using the new AT / GT series of
pneumatic actuators, the structure of the national utility model
patents, a double-acting and single-acting (spring reset), the use of
rack and pinion Structural transmission, more secure and reliable
performance; large-diameter valve with AW series of pneumatic actuators,
fork structure transmission, reasonable structure, large output
torque.
Pneumatic O-cut ball valve with a second shut off the
ball valve, with explosion-proof device, available gas cut off. It is
composed of ball valve and single acting piston pneumatic actuator. It
is widely used in industries such as natural gas, oil, chemical,
metallurgy, paper-making, mining, printing and dyeing,
biopharmaceutical, daily chemicals, food and beverage, water treatment
and air treatment Fluid cut off control, and supporting the use of
automated pneumatic instruments.
Third, the pneumatic O-cut off the ball valve works
Pneumatic
O-cut ball valve by the body, ball, valve shaft, seal ring, packing,
platen and other components. Actuators from the gas, piston, gear type,
output shaft, cylinder head, bearings, guide ring, piston bush,
adjusting bolts, "O" ring and other major components. Actuator and valve
connection shaft. Cylinder input pressure, the role of the piston to
produce a certain thrust, the gear-type output driven by the piston, the
gear output shaft in rotation, driven by the rotation of the valve
shaft, so that the valve ball with the rotation of the valve, change the
valve Flow area, to achieve the purpose of changing the medium flow
through the valve.
Fourth, the pneumatic O-cut ball valve Features
1, thrust bearing to reduce stem friction torque, valve stem long-term operation can be smooth and flexible.
2, seat sealing performance, using PTFE and other elastic materials made of seals.
3,
anti-static function: In the sphere, the valve stem, the spring between
the body, the process can switch the static electricity derived.
4,
the stem seal is reliable, as the stem only for rotational movement
without lifting movements, stem packing seal is not easy to damage.
5,
due to PTFE and other materials with good self-lubricating, and
friction loss of the ball is small, so the long service life of the ball
valve.
6, cut off fast, with one second cut off capacity, and good
sealing performance, explosion-proof device can be equipped with gas
pipe can be cut off.
Fifth, pneumatic O-cut ball valve parts and components
Serial number | Part Name | Serial number | Part Name | Serial number | Part Name | Serial number | Part Name | Serial number | Part Name |
1 | Body | 4 | Nut | 7 | Gasket | 10 | Positioning pieces | 13 | Valve stem |
2 | Sealing ring | 5 | Stud | 8 | filler | 11 | Ring | 14 | Screw |
3 | Sphere | 6 | Stone body | 9 | Packing gland | 12 | handle | 15 | Thrust washer |
Six, pneumatic O-cut ball valve performance parameters
Test pressure (Mpa) | Nominal pressure (Mpa) | Pressure class | JIS (Mpa) | |||||||
1.6 | 2.5 | 4.0 | 6.4 | 10.0 | 150 | 300 | 600 | 10K | 20K | |
Strength test | 2.4 | 3.8 | 6.0 | 9.6 | 15.0 | 3.1 | 7.8 | 15.3 | 2.4 | 3.8 |
Seal test | 1.8 | 2.8 | 4.4 | 7.0 | 11.0 | 2.2 | 5.6 | 11.2 | 1.5 | 2.8 |
Airtight test | 0.5 ~ 0.7 |
Seven, pneumatic O-cut ball valve technical parameters
Nominal diameter mm | DN15-DN300 | |||
Material code | C | P | R | |
The main parts | Body | WCB | ZG1Cr18Ni9Ti | ZG1Cr18Ni 12Mo2Ti |
Sphere | 2Cr13 | 1Cr18Ni9Ti | 1Cr18Ni12MoTi | |
Valve stem | 2Cr13 | 1Cr18Ni9Ti | 1Cr18Ni12MoTi | |
Sealing ring | Enhanced polytetrafluoroethylene para-benzene | |||
Filler | Polytetrafluoroethylene flexible graphite | |||
Applicable conditions | Suitable media | Steam, water | Nitric acids | Acetic acid |
proper temperature | -28 ° C - 300 ° C | |||
Actuator | Model | AW, DA / SR series, GTE series, TH series and so on | ||
Air pressure | 0.4-0.7MPa |
Eight, install the size table
DN (mm) | Size (mm) | Actuator model | ||||||||||||||
1.6MPa | 2.5MPa | 4.0MPa | ||||||||||||||
L | D | D1 | b | Z-фD | L | D | D1 | b | Z-фD | L | D | D1 | b | Z-фD | Optional DA / SR, QGSY, SY-CH, GTD / GTE AW / AWS, SY-YD, Series Actuators The above options are for reference only Specific constituencies according to the actual requirements | |
15 | 130 | 95 | 65 | 14 | 4-14 | 130 | 95 | 65 | 16 | 4-14 | 130 | 130 | 65 | 16 | 4-14 | |
20 | 130 | 105 | 75 | 14 | 4-14 | 130 | 105 | 75 | 16 | 4-14 | 150 | 150 | 75 | 16 | 4-14 | |
25 | 140 | 115 | 85 | 14 | 4-14 | 140 | 115 | 85 | 16 | 4-14 | 160 | 160 | 85 | 16 | 4-14 | |
32 | 165 | 135 | 100 | 16 | 4-18 | 165 | 135 | 100 | 18 | 4-18 | 180 | 180 | 100 | 18 | 4-18 | |
40 | 165 | 145 | 110 | 16 | 4-18 | 165 | 145 | 110 | 18 | 4-18 | 200 | 200 | 110 | 18 | 4-18 | |
50 | 203 | 160 | 125 | 16 | 4-18 | 203 | 160 | 125 | 20 | 4-18 | 230 | 230 | 125 | 20 | 4-18 | |
65 | 222 | 180 | 145 | 18 | 4-18 | 222 | 180 | 145 | 22 | 8-18 | 290 | 290 | 145 | 22 | 8-18 | |
80 | 241 | 195 | 160 | 20 | 8-18 | 241 | 195 | 160 | 22 | 8-18 | 310 | 310 | 160 | 22 | 8-18 | |
100 | 305 | 215 | 180 | 20 | 8-18 | 305 | 230 | 190 | 24 | 8-23 | 350 | 350 | 190 | 24 | 8-23 | |
125 | 356 | 245 | 210 | 22 | 8-18 | 356 | 270 | 220 | 28 | 8-25 | 400 | 270 | 220 | 28 | 8-25 | |
150 | 394 | 280 | 240 | 24 | 8-23 | 394 | 300 | 250 | 30 | 8-25 | 480 | 300 | 250 | 30 | 8-25 | |
200 | 457 | 335 | 295 | 28 | 12-23 | 457 | 360 | 310 | 34 | 12-25 | 600 | 375 | 320 | 38 | 12-30 |