五月天综合网站视频在线观看_国产一区二区三区毛毛片_精品日韩欧美一区二区三区四区_了解最新中文字幕午夜无码中文字_91福利午夜影院_国产在线精彩视频_新av一区二区三区_青青河边草免费观看高清电影下载_国产馆 极品 在线视频_国产精品长腿美乳

What are the main points of the installation of the safety valve and the design of the piping layout?

Column:Technical support Time:2018-01-05
shared:
the safety valve on the equipment or pipe should generally be erected. But for setting up safety valve at liquid pipe, heat exchanger or container, when the valve is closed, the place where pressure can be increased due to thermal ...

(1) the safety valve on the equipment or pipe should generally be erected. But for setting up safety valve at liquid pipe, heat exchanger or container, when the valve is closed, the place where pressure can be increased due to thermal expansion can be installed horizontally.


(2) the installation position of the safety valve should be as close as possible to the protected equipment or pipeline. If not close to the layout, it is required that the pressure drop of the pipeline between the protected equipment inlet and the safety valve inlet should not exceed 3% of the fixed value of the valve. ;

(3) the safety valve should not be installed at the dead end of a long horizontal pipe to prevent the accumulation of solid or liquid materials at the dead end, so as not to affect the normal work of the safety valve;

(4) the safety valve should be installed in the place of easy to repair and adjust, and there should be enough workspace around.

(5) because the large diameter safety valve has large weight, it is necessary to consider the possibility of hoisting after the disassembly of the large diameter safety valve, and the hanger should be set when necessary.

(6) long radius elbow should be used in the inlet pipe of the safety valve.

(7) the design of the outlet pipe of the safety valve should consider the certain value of the back pressure not exceeding the safety valve. For example, the back pressure of the common type spring safety valve is not more than 10% of the fixed value of the safety valve;

(8) into the closed system of the safety valve outlet pipe should be 45 degrees along the flow direction of medium pressure relief duct at the top of miter, lest the condensate within the duct pour into the branch, and can reduce the pressure of safety valve;

(9) the safety valve outlet pipe should have a "pocket", the safety valve outlet pipe is long, are advised to set up a certain slope (except dry gas system);

(10) when the discharge pipe of the relief valve is discharged to the atmosphere, it should be noted that the outlet can not be directed to the equipment, the platform, the ladder, the cable and so on.

(11) wet gas pressure relief system in exhaust pipe should not be "a" fluid, the safety valve installation height should be higher than the pressure relief system. If the outlet of the relief valve is lower than the pressure relief pipe or the discharge tube needs to be raised to the general pipe, it should be located at the low point easily.

(12) when the shut-off valve on the inlet pipe of the safety valve is equipped with shut-off valve, single gate valve should be selected and lead Fengkai should be installed. The valve stem should be installed horizontally, so that the slide plate can not slide up, so that the slide plate will slide down when the pin or valve plate is connected with the pin. When the safety valve with bypass valve, the valve should be sealed off.